TM 1-1520-238-T-7
11246
1130. ASE DC CIRCUIT BREAKER DOES NOT STAY CLOSED
1130
Tools:
Nomenclature
Part Number
Tool Kit, Electrical
SC518099CLA06
Repairers
Multimeter, Digital
AN/PSM-45
Extractor, Relay
CTJ-RO6
Personnel Required:
68X
Armament/Electrical Systems Repairer
References:
TM 1-1520-238-T-6
TM 1-1520-238-23
WARNING
Turn off power before detaching or
attaching wires and connectors. High
current 28 VDC or 115 VAC is present.
Failure to do so could result in death or
serious injury.
1. Open ASE DC circuit breaker. Check for short
between P134 and ground.
Does short exist?
YES
Refer to TM 1-1520-238-T-6 to
troubleshoot circuit protection
system (dc essential bus 3
pilot station).
NO
Go to step 2.
2. Check for short between P441B1 and ground.
Does short exist?
YES
Go to step 3.
NO
Go to step 4.
3. Check for short between (A137)J1A10 and
ground.
Does short exist?
YES
Replace pilot ASE panel
(TM 1-1520-238-23).
NO
Repair shorted wire between
P441B1 and P170A10.
Go to paragraph 1123.
4. Detach P431 and P441. Check for short
between (A402)J134 and ground.
Does short exist?
YES
Go to step 6.
NO
Go to step 5.
5. Detach P682. Check for short between
P431B1 and ground.
Does short exist?
YES
Repair shorted wire between:
P682 SP5 and P68275,
P682 SP5 and P682121,
P682 SP5 and P68273,
P682 SP5 and P68279,
P682 SP5 and P68277,
P431B1 and P682 SP5.
Go to paragraph 1123.
NO
(ACA) Replace DASEC
(TM 1-1520-238-23).
(ACB) Go to step 7.
6. Check for short between (A402):
Wire end K41/2B3 and ground,
wire end K41/2B2 and ground.
Does short exist?
YES
Repair shorted wire between
(A402):
TB27D and J134,
TB27G and J24B1,
TB27A and J27B1,
TB27K and K41/2B3,
J27B4 and K41/2B2.
Go to paragraph 1123.
NO
Replace relay XK41/2
(TM 1-1520-238-23).
7. (ACB) Attach P682. Detach filter adapter A705.
Check for short between P431B1 and ground.
Does short exist?
YES
Replace filter adapter
(TM 1-1520-238-23).
NO
Replace DASEC
(TM 1-1520-238-23).
END OF TASK