TM 1-1520-238-T-7
11248
Change 4
1131.
ASE BUCS CIRCUIT BREAKER DOES NOT STAY CLOSED
1131
8. Detach P413. Check for short between P441B2
and ground.
Does short exist?
YES
Repair shorted wire between
P441B2 and P413B14.
Go to paragraph 1123.
NO
Go to step 12.
9. Check for short between:
(A323) J5A3 and ground,
(A323) J5A4 and ground.
Does short exist?
YES
Repair shorted wire between:
(A323):
J5A3 and TB33J,
J5A7 and TB33K,,
J4B12 and TB34R,
J5A4 and TB34P,
J5A10 and TB34N.
Go to paragraph 1123.
NO
Go to step 10.
10. Attach P493. Check for short between:
P499A4 and ground,
P499A10 and ground.
Does short exist?
YES
Repair shorted wire between:
P68268 and P682 SP4,
P68266 and P682 SP4,
P499A10 and P682 SP4,
P68661 and J402B17,
P402B17 and J75622,
J215SP1 and P75624,
P75622 and J215SP1,
J75624 and P402B19,
J402B19 and P499A4.
Go to paragraph 1123.
NO
Go to step 11.
11. Check for short between P68661 and ground.
Does short exist?
YES
Go to step 14.
NO
Repair shorted wire between
P499A7 and P68662.
Go to paragraph 1123.
12. Detach P472. Check for short between
(A326)J10B12 ground.
Does short exist?
YES
Repair shorted wire between
(A326):
J10B12 and TB121D,
J10B14 and TB121F,
J10B5 and TB121L,
J10B13 and TB121M,
J10B15 and TB121C,
J10B6 and TB121B,
J15A17 and TB121K,
J15A18 and TB121A,
J15A19 and TB121J,
J15A20 and TB121H.
Go to paragraph 1123.
NO
Go to step 13.
13. Check for short between:
P413B5 and ground,
P472A17 and ground,
P413B12 and ground,
P472A18 and ground,
P413B13 and ground.
Does short exist?
YES
Go to paragraph 1132.
NO
Go to paragraph 1133.