TM 1-1520-238-T-7
11250
1132.
ASE BUCS CIRCUIT BREAKER DOES NOT STAY CLOSED FAULT IN CPG
1132
BUCS WIRING
Tools:
Nomenclature
Part Number
Tool Kit, Electrical
SC518099CLA06
Repairers
Multimeter, Digital
AN/PSM-45
Personnel Required:
68X
Armament/Electrical Systems Repairer
References:
TM 1-1520-238-23
Equipment Conditions:
Ref
Condition
TM 1-1520-238-23
Nontransparent
barrier removed
WARNING
Turn off power before detaching or
attaching wires and connectors. High
current 28 VDC or 115 VAC is present.
Failure to do so could result in death or
serious injury.
1. Detach P413. Check for short between
P413B5 and ground.
Does short exist?
YES
Go to step 2.
NO
Go to step 3.
2. Check for short between J2661 and ground.
Does short exist?
YES
Repair shorted wire between
P413B5 and J2661.
Go to paragraph 1123.
NO
Go to step 5.
3. Check for short between P413B12 and ground.
Does short exist?
YES
Go to step 4.
NO
Go to step 6.
4. Check for short between J2681 and ground.
Does short exist?
YES
Repair shorted wire between
P413B12 and J2681.
Go to paragraph 1123.
NO
Replace CPG collective SPAD
(TM 1-1520-238-23).
5. Detach P686. Check for short between J2665
and ground.
Does short exist?
YES
Repair shorted wire between:
J2665 and P237 SP1,
P237 SP1 and J447B13,
P447B13 and P68651.
Go to paragraph 1123.
NO
Replace CPG lateral SPAD
(TM 1-1520-238-23).
6. Check for short between P413B13 and ground.
Does short exist?
YES
Go to step 7.
NO
Go to step 9.
7. Detach P447 and P108. Check for short
between P413B13 and ground.
Does short exist?
YES
Repair shorted wire between:
P413B13 and P234 SP1,
J108i and P234 SP1,
J447B19 and P234 SP1.
Go to paragraph 1123.
NO
Go to step 8.
8. Check for short between P68654 and ground.
Does short exist?
YES
Repair shorted wire between
P68654 and P447B19.
Go to paragraph 1123.
NO
Replace CPG BUCS select
trigger switch
(TM 1-1520-238-23).