TM 1-1520-238-T-711–25811–39. ASE PANEL YAW SWITCH – DOES NOT STAY ON11–39Tools:NomenclaturePartNumberTool Kit, ElectricalSC518099CLA06Repairer’sMultimeter, DigitalAN/PSM-45Personnel Required:68XArmament/Electrical Systems RepairerOne person to assistReferences:TM 1-1520-238-23WARNINGTurn off power before detaching orattaching wires and connectors. Highcurrent 28 VDC or 115 VAC is present.Failure to do so could result in deathor serious injury.To prevent the possibility of shorting,use extreme care when checkingvoltage at mass terminationconnectors. Failure to do so couldresult in damage to equipment orpossible injury to personnel.1. Check for 28 VDC at P170–A9.Is voltage present?YESReplace pilot ASE panel(TM 1-1520-238-23).NOGo to step 2.2. Check for open between P170–A9 andP683–121.Does open exist?YESRepair open wire.Go to paragraph 11–23.NO(ACA) Replace DASEC(TM 1-1520-238-23).(ACB) Go to step 3.3. (ACB) Detach filter adapter A706. Check foropen between A706–121 and P170–A9.Does open exist?YESReplace filter adapter(TM 1-1520-238-23).NOReplace DASEC(TM 1-1520-238-23).END OF TASK