TM 1-1520-238-T-7
11262
1143. RTR BRK CIRCUIT BREAKER DOES NOT STAY CLOSED WITH RTR BK
733
SWITCH SET TO BRAKE AND POWER LEVERS SET TO OFF
Tools:
Nomenclature
Part Number
Tool Kit, Electrical
SC518099CLA06
Repairers
Multimeter, Digital
AN/PSM-45
Personnel Required:
68X
Armament/Electrical Systems Repairer
References:
TM 1-1520-238-T-5
TM 1-1520-238-23
WARNING
Turn off power before detaching or
attaching wires and connectors. High
current 28 VDC or 115 VAC is present.
Failure to do so could result in death or
serious injury.
1. Open RTR BRK circuit breaker (CB37). Check
for short between (A402)J24A16 and ground.
Does short exist?
YES
Go to step 5.
NO
Go to step 2.
2. Detach P170, P173 and P436. Check for short
between P441A16 and ground.
Does short exist?
YES
Repair shorted wire between:
P441A16 and P173 SP1,
P173 SP1 and P173b,
P173 SP1 and J914B8,
P914B8 and J436A15,
P173 SP1 and P170A7.
Go to paragraph 1123.
NO
Go to step 3.
3. Check for short between P436A15 and ground.
Does short exist?
YES
Refer to TM 1-1520-238-T-5 to
troubleshoot hydraulic and
pneumatic system.
NO
Go to step 4.
4. Check for short between (A137)J1A2 and
ground.
Does short exist?
YES
Replace pilot ASE panel
(TM 1-1520-238-23).
NO
Go to step 6.
5. Detach P990 and P986. Check for short
between (A402)J24A16 and ground.
Does short exist?
YES
Repair shorted wire between:
P990W and P431A4,
P986W and P431A18.
(A402):
J27A18 and TB229D,
J24A14 and TB229B,
J27A4 and TB229C.
Go to paragraph 1123.
NO
Go to paragraph 1188.
6. Attach P173. Check for short between P170A7
and ground.
Does short exist?
YES
Replace pilot power quadrant
(TM 1-1520-238-23).
NO
Go to step 7.
7. Detach P686. Check for short between
P170A2 and ground.
Does short exist?
YES
Repair shorted wire between:
P170A2 and J447A6,
P447A6 and P686114.
Go to paragraph 1123.
NO
(ACA) Replace DASEC
(TM 1-1520-238-23).
(ACB) Go to step 8.