TM 1-1520-238-T-7
11254
Change 4
1135. PILOT AND CPG CAUTION/WARNING PANEL ASE INDICATOR IS LIGHTED
1135
Tools:
Nomenclature
Part Number
Tool Kit, Electrical
SC518099CLA06
Repairers
Multimeter, Digital
AN/PSM-45
Personnel Required:
68X
Armament/Electrical Systems Repairer
References:
TM 1-1520-238-T-6
TM 1-1520-238-23
WARNING
Turn off power before detaching or
attaching wires and connectors. High
current 28 VDC or 115 VAC is present.
Failure to do so could result in death or
serious injury.
1. Detach P18.
Is ASE indicator still lighted?
YES
Refer to TM 1-1520-238-T-6 to
troubleshoot pilot
caution/warning system.
Go to paragraph 1123.
NO
Go to step 2.
2. Detach P683. Check for short between P1846
and ground.
Does short exist?
YES
Repair shorted wire between:
P1846 and P908A16,
J908A16 and J447A18,
P447A18 and P683116,
Go to paragraph 1123.
NO
(ACA) Replace DASEC
(TM 1-1520-238-23)
(ACB) Go to step 3.
3. (ACB) Attach P683. Detach filter adapter A706.
Check for short between A706116 and ground.
Does short exist?
YES
Replace filter adapter
(TM 1-1520-238-23).
Go to paragraph 1123.
NO
Replace DASEC
(TM 1-1520-238-23).
Go to paragraph 1123.
END OF TASK