TM 1-1520-238-T-7
11267
1147. PILOT AND CPG BUCS FAIL INDICATORS- ARE LIGHTED WITH CPG BUCS
1147
SELECT TRIGGER SWITCH RELEASED
Tools:
Nomenclature
Part Number
Tool Kit, Electrical
SC518099CLA06
Repairers
Multimeter, Digital
AN/PSM-45
Personnel Required:
68X
Armament/Electrical Systems Repairer
References:
TM 1-1520-238-T-6
TM 1-1520-238-23
Equipment Conditions:
Ref
Condition
TM 1-1520-238-23
Access provisions
R295 door open
WARNING
Turn off power before detaching or
attaching wires and connectors. High
current 28 VDC or 115 VAC is present.
Failure to do so could result in death or
serious injury.
1. Check for 28 VDC at P686113.
Does short exist?
YES
Go to step 3.
NO
Go to step 2.
2. Check for 5 to 30 VDC at P20t.
Does short exist?
YES
Refer to TM 1-1520-238-T-6 to
troubleshoot pilot
caution/warning system.
NO
Go to step 4.
3. Detach P686 and P413. Check for short
between J108i and J108h.
Does short exist?
YES
Repair shorted wire between:
J108i and P234 SP1,
J108h and J459A1,
P234 SP1 and P413B13,
P234 SP1 and J447B19,
P459A1 and P68613,
P447B19 and P68654.
Go to paragraph 1123.
NO
Replace CPG BUCS select
trigger switch
(TM 1-1520-238-23).
4. Check for short between:
P683115 and ground,
P20t and ground.
Does short exist?
YES
Repair shorted wire between:
P20t and P20 SP1,
P456A12 and P20 SP1,
P31t and P20 SP1,
P456A12 and P683115.
Go to paragraph 1123.
NO
(ACA) Replace DASEC
(TM 1-1520-238-23).
(ACB) Go to step 5.
5. (ACB) Detach filter adapter A706. Check for
short between A706115 and case.
Does short exist?
YES
Replace filter adapter
(TM 1-1520-238-23).
NO
Replace DASEC
(TM 1-1520-238-23).
END OF TASK