TM 1-1520-238-T-7
11268
1148.
PILOT BUCS FAIL INDICATOR IS LIGHTED WITH CPG BUCS SELECT
1148
TRIGGER SWITCH RELEASED
Tools:
Nomenclature
Part Number
Tool Kit, Electrical
SC518099CLA06
Repairers
Multimeter, Digital
AN/PSM-45
Personnel Required:
68X
Armament/Electrical Systems Repairer
References:
TM 1-1520-238-T-6
WARNING
Turn off power before detaching or
attaching wires and connectors. High
current 28 VDC or 115 VAC is present.
Failure to do so could result in death or
serious injury.
Detach J164 and P20. Check for short between
J164B5 and ground.
Does short exist?
YES
Repair shorted wire between
J164B5 and P20F.
Go to paragraph 1123.
NO
Refer to TM 1-1520-238-T-6 to
troubleshoot pilot
caution/warning system.
END OF TASK