TM 1-1520-238-T-7
11269
1149.
CPG BUCS FAIL INDICATOR IS LIGHTED WITH CPG BUCS SELECT TRIGGER
1149
SWITCH RELEASED
Tools:
Nomenclature
Part Number
Tool Kit, Electrical
SC518099CLA06
Repairers
Multimeter, Digital
AN/PSM-45
Personnel Required:
68X
Armament/Electrical Systems Repairer
References:
TM 1-1520-238-T-6
WARNING
Turn off power before detaching or
attaching wires and connectors. High
current 28 VDC or 115 VAC is present.
Failure to do so could result in death or
serious injury.
Detach J166 and P31. Check for short between
J166B5 and ground.
Does short exist?
YES
Repair shorted wire between
J166B5 and P31F.
Go to paragraph 1123.
NO
Refer to TM 1-1520-238-T-6 to
troubleshoot CPG
caution/warning system.
END OF TASK