TM 1-1520-238-T-7
Change 5
11399
11106. SCU 1 NO-GO LH CATWALK APPEARS ON HOD (AAC)
11106
Tools:
Nomenclature
Part Number
Tool Kit, Electrical
SC518099CLA06
Repairers
Multimeter, Digital
AN/PSM-45
Personnel Required:
68X
Armament/Electrical Systems Repairer
One person to assist
References:
TM 1-1520-238-T-4
TM 1-1520-238-23
Equipment Conditions:
Ref
Condition
TM 1-1520-238-23
Access provisions
electrical power distribution
box cover removed
TM 1-1520-238-T-4
Maintenance headset
connected
WARNING
Turn off power before detaching or
attaching wires and connectors. High
current 28 VDC or 115 VAC is present.
Failure to do so could result in death or
serious injury.
1. Open STAB MAN DC (A76)CB6, STAB AUTO
DC (A76)CB3, STAB AUTO AC (A76)CB2, and
ENG WARN (A76)CB52 circuit breakers.
Detach:
P682 from (A705)J3,
P986 from (A637)J2,
P987 from (A637)J3.
Check for open between:
P68250 and P987K,
P68249 and P987V,
P68248 and P987X,
P431A18 and P986W,
(A402)TB229D and (A402)J27A18,
(A402)TB229B and (A402)J27A16.
Does open exist?
YES
Repair open wire.
Go to paragraph 1188.
NO
Go to step 2.
2. Check for short between:
P987K and ground,
P987V and ground,
P987X and ground.
Does short exist?
YES
Repair shorted wire.
Go to paragraph 1188.
NO
Go to step 3.
3. Check for open between P68264 and ground.
Does open exist?
YES
Repair open wire.
Go to paragraph 1188.
NO
Go to step 4.
4. Detach P686 from (A707)J2.
Check for open between:
P987E and P6868,
P987G and P6867.
Does open exist?
YES
Repair open wire.
Go to paragraph 1188.
NO
Go to step 5.