TM 1-1520-238-T-7
Change 5
11389
11101. ND/NU SWITCH SET TO NU TOP PISTON FAILS TO MOVE STABILATOR
11101
(BOTTOM STAB ACTUATOR EXTENDS FULLY)
Tools:
Nomenclature
Part Number
Tool Kit, Electrical
SC518099CLA06
Repairers
Multimeter, Digital
AN/PSM-45
Extractor, Relay
CTJ-RO6
Personnel Required:
68X
Armament/Electrical Systems Repairer
One person to assist
References:
TM 1-1520-238-23
Equipment Conditions:
Ref
Condition
TM 1-1520-238-23
Access provisions
L325 door open
WARNING
Turn off power before detaching or
attaching wires and connectors. High
current 28 VDC or 115 VAC is present.
Failure to do so could result in death or
serious injury.
1. Detach P995 from (L46)J995. Momentarily press
pilot collective NU/ND switch to NU. Check for
28 VDC between P995J(HI) and P995K(LO).
Is voltage present?
YES
Replace top STAB ACTUATOR
(L46) (TM 1-1520-238-23).
NO
Go to step 2.
2. Open STAB MAN DC (A76)CB6, STAB AUTO
DC (A76)CB3, STAB AUTO AC (A76)CB2, and
ENG WARN (A76)CB52 circuit breakers. Detach
P427 from (A402)J28.
Check for open between (A402):
TB224E and J28F.
Does open exist?
YES
Repair open wire.
Go to paragraph 1188.
NO
Go to step 3.
3. Detach P485 from (A323)J7.
Check for open between P427F and P485P.
Does open exist?
YES
Repair open wire.
Go to paragraph 1188.
NO
Go to step 4.
4. Check for open between (A323):
J7P and XK13B1.
Does open exist?
YES
Repair open wire.
Go to paragraph 1188.
NO
Go to step 5.
5. Check for open between (A323):
XK13B2 and J7M.
Does open exist?
YES
Repair open wire.
Go to paragraph 1188.
NO
Go to step 6.
6. Detach P1077 from (A329)J1.
Check for open between P485M and P1077c.
Does open exist?
YES
Repair open wire.
Go to paragraph 1188.
NO
Go to step 7.