TM 1-1520-238-T-7
Change 5
11403
11110. RATE GYRO 2 NO-GO RH AFT CATWALK APPEARS ON HOD
11110
Tools:
Nomenclature
Part Number
Tool Kit, Electrical
SC518099CLA06
Repairers
Multimeter, Digital
AN/PSM-45
Personnel Required:
68X
Armament/Electrical Systems Repairer
One person to assist
References:
TM 1-1520-238-23
Equipment Conditions:
Ref
Condition
TM 1-1520-238-23
Access provisions
L325, T325, T290L T290R,
T250L and
T250R doors open
WARNING
Turn off power before detaching or
attaching wires and connectors. High
current 28 VDC or 115 VAC is present.
Failure to do so could result in death or
serious injury.
1. Detach J998 from (A640)P1.
Close STAB AUTO AC circuit breaker
(A76)CB2.
Check for 26 VAC between:
J9981 and J9983,
J9982 and J9983.
Is voltage present?
YES
Go to step 2.
NO
Go to step 5.
2. Detach J998 from (A640)P1.
Check for 26 VAC between J9984 and J9985.
Is voltage present?
YES
Go to step 7.
NO
Go to step 3.
3. Open STAB MAN DC (A76)CB6, STAB AUTO
DC (A76)CB3, STAB AUTO AC (A76)CB2, and
ENG WARN (A76)CB52 circuit breakers.
Detach J998 from (A640)P1.
Check for open between:
P991L and J9984,
P991M and J9985.
Does open exist?
YES
Repair open wire.
Go to paragraph 1188.
NO
Go to step 4.
4. Detach P991 from (A638)J3.
Check for short between:
J9984 and ground,
J9985 and ground.
Does short exist?
YES
Repair shorted wire between:
J9984 and P919B2,
J919B2 and P992L,
J9985 and P919B1,
J919B1 and P992M,
Go to paragraph 1188.
NO
Replace STAB CONT UNIT 2
(A638) (TM 1-1520-238-23).