TM 1-1520-238-T-7
Change 5
11409
11116. MAN STAB INDICATORS ON AUTO MODE DOES NOT ENGAGE AND STAB POS
11116
INDICATORS DO NOT GO TO 25 2 ND
Tools:
Nomenclature
Part Number
Tool Kit, Electrical
SC518099CLA06
Repairers
Multimeter, Digital
AN/PSM-45
Extractor, Relay
CTJ-RO6
Personnel Required:
68X
Armament/Electrical Systems Repairer
One person to assist
References:
TM 1-1520-238-23
TM 1-1520-238-T-6
Equipment Conditions:
Ref
Condition
TM 1-1520-238-23
Access provisions
L325, T290L and
T290R doors open
WARNING
Turn off power before detaching or
attaching wires and connectors. High
current 28 VDC or 115 VAC is present.
Failure to do so could result in death or
serious injury.
1. Open STAB MAN DC (A76)CB6, STAB AUTO
DC (A76)CB3, STAB AUTO AC (A76)CB2, and
ENG WARN (A76)CB52 circuit breakers.
Detach P1077 from (A329)J1.
Check for short between P1077R and ground.
Does short exist?
YES
Go to step 2.
NO
Go to step 3.
2. Detach J908 from P908.
Check for short between:
P1077R and ground,
P908A5 and ground.
Does short exist?
YES
Repair shorted wire.
Go to paragraph 1188.
NO
Troubleshoot pilot and CPG
CAUTION/WARNING system
(TM 1-1520-238-T-6).
3. Detach:
P2 from (A402)J2,
P427 from (A402)J28,
P431 from (A402)J27,
P485 from (A323)J7,
P985 from (A637)J1,
P989 from (A638)J1.
Check for open between:
STAB AUTO DC (A76)CB3 and P2f,
(A402)J2f and (A402)TB222A,
(A402)TB222D and (A402)J27B9,
(A402)TB222C and (A402)J27B11,
(A402)TB222E and (A402)J28C,
(A402)TB222F and (A402)J28D,
P427D and P485E,
(A323)J7E and (A323)XK11/2B2,
(A323)XK11/2B1 and (A323)J7K,
P485K and P985G,
P427C and P485L,
(A323)J7L and (A323)TB23A,
(A323)TB23D and (A323)J7V,
P485V and P1077a,
(A329)J1a and (A329)XK11/2B2,
(A329)XK11/2B1 and (A329)J1n,
P1077n and P989G,
P431B9 and P989E,
P431B11 and P985E.
Does open exist?
YES
Repair open wire.
Go to paragraph 1188.
NO
Go to step 4.