TM 1-1520-238-T-7
Change 5
11405
11112. TOP STAB ACTUATOR NO-GO TAIL SECTION APPEARS ON HOD
11112
Tools:
Nomenclature
Part Number
Tool Kit, Electrical
SC518099CLA06
Repairers
Multimeter, Digital
AN/PSM-45
Personnel Required:
68X
Armament/Electrical Systems Repairer
One person to assist
References:
TM 1-1520-238-23
Equipment Conditions:
Ref
Condition
TM 1-1520-238-23
Access provisions
R545 and L545 doors
open
WARNING
Turn off power before detaching or
attaching wires and connectors. High
current 28 VDC or 115 VAC is present.
Failure to do so could result in death or
serious injury.
1. Open STAB MAN DC (A76)CB6, STAB AUTO
DC (A76)CB3, and STAB AUTO AC (A76)CB2
circuit breakers. Detach:
P682 from (A69)J3,
P497from (A323)J3.
Check for open between:
P68290 and P497B19,
P68291 and P497B18,
(A323)J3B19 and (A323)TB18H,
(A323)J3B18 and (A323)TB18C.
Does open exist?
YES
Repair open wire.
Go to paragraph 1188.
NO
Replace top STAB ACTUATOR
(L46) (TM 1-1520-238-23).
END OF TASK