TM 1-1520-238-T-7
11436
Change 5
11133. PILOT ND/NU SWITCH DOES NOT MOVE STAB UP STAB AUTO AC (CB2) AND STAB
11133
AUTO DC (CB3) CIRCUIT BREAKERS OPEN
Tools:
Nomenclature
Part Number
Tool Kit, Electrical
SC518099CLA06
Repairers
Multimeter, Digital
AN/PSM-45
Extractor, Relay
CTJ-RO6
Personnel Required:
68X
Armament/Electrical Systems Repairer
One person to assist
References:
TM 1-1520-238-23
Equipment Conditions:
Ref
Condition
TM 1-1520-238-23
WARNING
Turn off power before detaching or
attaching wires and connectors. High
current 28 VDC or 115 VAC is present.
Failure to do so could result in death or
serious injury.
1. Open STAB MAN DC (A76)CB6 and STAB
MAN AC (A76)CB7 circuit breakers.
Detach:
P2 from (A402)J2,
P437 from (A402)J25,
P427 from (A402)J28.
Check for open between:
STAB MAN DC (A76)CB6 and P2g,
(A402)J2g and (A402)TB223A,
(A402)TB223D and (A402)J25A,
(A402)P437A and J993B,
(A402)TB223E and (A402)TB224A.
Does open exist?
YES
Repair open wire.
Go to paragraph 1188.
NO
Go to step 2.
2. Hold pilot collective ND/NU switch on to NU.
Check for open between (A641):
J993B and J993A.
Does open exist?
YES
Replace pilot MAN STAB switch
(TM 1-1520-238-23).
NO
Go to step 3.
3. Detach P1077. Check for open between (A329):
TB14A and J1v,
P1077v and GS4A.
Does open exist?
YES
Repair open wire.
Go to paragraph 1188.
NO
Go to step 4.
4. Check for open between:
(A641)J993A and P437B,
(A402)J25B and (A402)TB221D,
(A402)TB221A and (A402)J28G,
(A402)P427G and (A323)P485R,
(A323)J7R and (A323)XK13X1,
(A323)XK13X2 and GS4A.
Does open exist?
YES
Repair open wire.
Go to paragraph 1188.
NO
Replace MAN CONT NOSE UP
relay (A323)K13
(TM 1-1520-238-23).
END OF TASK