TM 1-1520-238-T-7
Change 5
11431
11130. CPG NU/ND INOPERATIVE STAB POS INDICATORS DO NOT MOVE
11130
Tools:
Nomenclature
Part Number
Tool Kit, Electrical
SC518099CLA06
Repairers
Multimeter, Digital
AN/PSM-45
Personnel Required:
68X
Armament/Electrical Systems Repairer
One person to assist
References:
TM 1-1520-238-23
WARNING
Turn off power before detaching or
attaching wires and connectors. High
current 28 VDC or 115 VAC is present.
Failure to do so could result in death or
serious injury.
1. Open STAB MAN DC (A76)CB6, STAB AUTO
DC (A76)CB3, STAB AUTO AC (A76)CB2, and
ENG WARN (A76)CB52 circuit breakers.
Detach:
P437 from (A402)J25,
J994 from (A641)P994.
Check for open between:
(A402)TB223F and (A402)J25D,
(A402)TB221F and (A402)J25C,
(A402)TB225E and (A402)J25F,
P437D and J994B,
P437C and J994A,
P437F and J994D.
Does open exist?
YES
Repair open wire.
Go to paragraph 1188.
NO
Replace CPG MAN STAB
CONT switch (A641)
(TM 1-1520-238-23).
END OF TASK