TM 1-1520-238-T-7
Change 5
11433
11132. STAB POS NOT 19 2 NU FOR 70 KNOTS AND COLLECTIVE CENTERED
11132
Tools:
Nomenclature
Part Number
Tool Kit, Electrical
SC518099CLA06
Repairers
Multimeter, Digital
AN/PSM-45
Personnel Required:
68X
Armament/Electrical Systems Repairer
One person to assist
References:
TM 1-1520-238-23
WARNING
Turn off power before detaching or
attaching wires and connectors. High
current 28 VDC or 115 VAC is present.
Failure to do so could result in death or
serious injury.
1. Check for 5.25 .30 VDC between P990D(HI)
and P990E(LO).
Is voltage present?
YES
Go to step 2.
NO
Go to step 3.
2. Check for 5.25 .30 VDC between P986D(HI)
and P986E(LO).
Is voltage present?
YES
Replace STAB CONT UNIT 1
(A637) or
STAB CONT UNIT 2
(TM 1-1520-238-23).
NO
Go to step 10.
3. Detach P984 from (MT18)J1.
Close STAB AUTO AC (A76)CB2 circuit
breaker. Check for +15 2 VDC between
P984A and ground.
Is voltage present?
YES
Go to step 5.
NO
Go to step 4.
4. Detach P991 from (A638)J3.
Check for open between:
P991U and P984A,
P991U and P986D,
P983C and P986E.
Does open exist?
YES
Repair open wire.
Go to paragraph 1188.
NO
Replace STAB CONT UNIT 2
(TM 1-1520-238-23).
5. Check for short between P984D and ground.
Does short exist?
YES
Go to step 6.
NO
Go to step 8.
6. Detach P990 from (A638)J2.
Check for short between P984D and ground.
Does short exist?
YES
Go to step 7.
NO
Replace STAB CONT UNIT 2
(TM 1-1520-238-23).
7. Detach P682 from (A69)J3.
Check for short between P984D and ground.
Does short exist?
YES
Repair shorted wire between:
P984D and P498A15,
(A323)J498A15 and
(A323)TB15G,
(A323)TB15F and
(A323)J3B9,
P497B9 and P682127,
(A323)TB15H and
(A323)J2B13,
P494B13 and P990D.
Go to paragraph 1188.
NO
Replace DASEC (A69)
(TM 1-1520-238-23).