TM 1-1520-238-23
2-563
2.152.
CPG GLARESHIELD CURTAIN/TRAY REMOVAL/INSTALLATION continued
2.152.4. Cleaning
a. Wipe removed and attaching parts and sur-
faces with a clean rag.
2.152.5. Inspection
a. Check curtain/tray for cracks and tears.
(1) Tears in curtain up to 0.50 INCH are allowed.
If tear exceeds 0.50 INCH, replace curtain.
(2) Cracks in curtain tray up to 0.25 INCH al-
lowed if not in a location that could cause
hand injury.
b. Check straps for cracks.
(1) Small cracks are allowed if they do not affect
deployment of curtain.
2.152.6. Installation
a. Install curtain/tray (1) on frame (2).
(1) Install tray (1) on frame (2).
(2) Install four screws (3) through washers (4),
tray (1), and frame (2).
b. Install curtain/tray (5) on frame (6).
(1) Install two straps (12) on frame (6).
(2) Install tray (5) on frame (6).
(3) Install four screws (10) through washers (11),
tray (5), straps (12), and frame (6).
(4) Install screw (7) through washer (8), washer
(9), tray (5), and frame (6).
c. Inspect (QA).
END OF TASK
1
M04-3287-4
2
4
3
6
5
12
10
11
8
9
M04-3287-5
7