TM 1-1520-238-23
5-44.15
5.7A.
MAIN ROTOR BLADE SPAR TO SPAR DEBOND REPAIR (AVIM) continued
t. Apply power to tool (7).
(1) Ensure all switches CONTROLLER PWR
(18), POWER SELECT (19), and HEATER
POWER, (20) are in the OFF or center posi-
tion.
(2) Remove cap (25) from 120V INPUT (21) or
220V INPUT (22) on tool (7).
(3) Connect electrical power source to 120V IN-
PUT (21) or 220V INPUT (22) on tool (7).
(4) Position the POWER SELECT switch (19) to
120V or 220V position as appropriate.
(5) Position CONTROLLER PWR switch (18) to
the ON position.
GO TO NEXT PAGE
M04 5206 28
20
18
7
7
22
19
21
25
25
M04 5206 29
M04 5206 30
18