TM 1-1520-238-23
9-48
Change 4
9.13.
CB3, CB201, CB202, CB203, OR CB204 REMOTE CONTROL CIRCUIT BREAKER
REPLACEMENT
9.13.1. Description
This task covers:
Removal. Cleaning. Inspection. Installation.
9.13.2. Initial Setup
Tools:
Electrical tool kit (item 378, App H)
Light duty laboratory apron (item 27, App H)
Chemical protective gloves (item 154, App H)
Adjustable air filtering respirator (item 262, App H)
Personnel Required:
68X
Armament/Electrical System Repairer
68X3F
Armament/Electrical System Repairer/
Technical Inspector
Materials/Parts:
Brush (item 34, App F)
Gloves (item 83, App F)
Insulating compound kit (item 97, App F)
References:
TM 9-1427-475-20
TM 55-1500-323-24
Equipment Conditions:
Ref
Condition
1.57
Helicopter safed
1.70
Helicopter external electrical power re-
moved
2.2
Access covers LW7 or LW8 or RW7 or RW8
removed
or
9.9
Electrical power distribution box cover re-
moved
NOTE
This is typical for CB3 remote control
circuit breaker in the power distribution
box and CB201, CB202, CB203, and
CB204 located in the wings.
CB201, CB202, CB203, and CB204
have electrical cable nipples that pro-
tect terminal studs. CB3 does not.
9.13.3. Removal
a. Enter pilot station (para 1.56). Observe all
safety precautions.
GO TO NEXT PAGE
M04-3727-1
M04-3727-2