TM 1-1520-238-23
9-50
Change 4
9.13.
CB3, CB201, CB202, CB203, OR CB204 REMOTE CONTROL CIRCUIT BREAKER
REPLACEMENT continued
9.13.6. Installation
NOTE
If replacing CB3 remote control circuit
breaker, go to step b.
a. Apply insulating compound on base of new
circuit breaker (10). Use brush (item 34, App F)
and insulating compound kit (item 97, App F).
b. Install circuit breaker (10) on mount (11).
(1) Position circuit breaker (10) on mount (11).
(2) Install two screws (12) and washers (13).
c. Attach identified wires (3) to terminal studs
(4).
(1) Install terminal lugs (9), two washers (8),
lockwashers (7), and nuts (6) on terminal
studs (4).
(2) Slide electrical cable nipples (5) over terminal
studs (4).
d. Pin identified wires (1) to connector (2)
(TM 55-1500-323-24).
e. Inspect (QA).
f. Install electrical power distribution box cover
(para 9.9), or access covers LW7, LW8, RW7,
and RW8 (para 2.2).
g. Perform HME system FD/LS maintenance op-
erational check (TM 9-1427-475-20).
END OF TASK
M04-3727-5
11
10
5
1
2
6
7
8
5
3
9
12
13
4