TM 1-1520-238-23
9-111
9.30.
TRANSFORMER-RECTIFIER NO. 1 REMOVAL/INSTALLATION continued
9.30.6. Installation
a. Install transformer-rectifier (3) on support
(12).
(1) Install four bolts (15) and washers (16).
b. Perform
electrical
bonding
check
(TM 55-1500-323-24).
(1) Bond shall be 0.0025 OHM or less. Use
ohmmeter.
c. Check for ground at connector P6 (13) pin D
and negative terminal lugs (6). Use multimeter.
d. Attach wires (1) to positive and negative ter-
minals (2) of transformer-rectifier (3).
(1) Install identified terminal lugs (6), two wash-
ers (5), and nuts (4).
(2) Attach connector P6 (13) to connector
(PS1)J1 (14).
(3) Lockwire connector (13) to bolt (15). Use wire
(item 222, App F).
e. Install three clamps (7) on main transmission
left forward strut (8).
(1) Install screw (11) through washer (10) and
clamps (7).
(2) Install nut (9).
f. Inspect (QA).
g. Perform DC power generation maintenance
operational check (TM 1-1520-238-T).
h. Install access panels L200 and L165 (para 2.2).
END OF TASK
3
M04-1095-5
12
15
16
3
1
13
M04-1095-10
2
5
4
4
5
14
6
6
M04-1095-9
7
10
11
7
7
9
8