PILOT ELEC PWR PANEL EXT PWR/RESET SWITCH REPLACEMENT continued - TM-1-1520-238-23-5_274
PILOT ELEC PWR PANEL GEN 1, GEN 2, OR BATT/EXT PWR SWITCHES REPLACEMENT
TM-1-1520-238-23-5 Helicopter Attack AH-64A Apache (NSN 1520-01-106-9519) (EIC: RHA) Manual
Page Navigation
253
254
255
256
257
258
259
260
261
262
263
TM 1-1520-238-23
9-124
9.35.
PILOT ELEC PWR PANEL EXT PWR/RESET SWITCH REPLACEMENT – continued
c.
Install connector (1) on panel (2).
(1) Position connector (1) on panel (2).
(2) Install three screws (3) through panel (2),
lockwashers
(4), flat washers (5), into con-
nector (1).
d.
Inspect (QA).
e.
Install pilot ELEC PWR light indicating panel
(para 9.34)
.
f.
Install ELEC PWR panel
(para 9.33)
.
g.
Perform external power and ground service
utility receptacle maintenance operational
check
(TM 1-1520-238-T)
.
END OF TASK