TM 1-1520-238-23
9-124
9.35.
PILOT ELEC PWR PANEL EXT PWR/RESET SWITCH REPLACEMENT continued
c. Install connector (1) on panel (2).
(1) Position connector (1) on panel (2).
(2) Install three screws (3) through panel (2),
lockwashers (4), flat washers (5), into con-
nector (1).
d. Inspect (QA).
e. Install pilot ELEC PWR light indicating panel
(para 9.34).
f. Install ELEC PWR panel (para 9.33).
g. Perform external power and ground service
utility receptacle maintenance operational
check (TM 1-1520-238-T).
END OF TASK
1
4
3
2
M04-1312-5
5