TM 1-1520-238-23
9-121
9.34.
PILOT ELEC PWR LIGHT INDICATING PANEL REMOVAL/INSTALLATION continued
9.34.4. Cleaning
a. Wipe removed and attaching parts with a clean
rag.
9.34.5. Inspection
a. Check removed and attaching parts for dam-
age (para 9.1).
b. Check mounting surface for nicks, dents, and
damaged or stripped threads. Thread damage
not to exceed 50 percent of one thread.
c. Check removed and attaching parts for corro-
sion (para 1.49).
9.34.6. Installation
a. Install panel (1) on pilot panel (2).
(1) Position panel (1) on panel (2).
(2) Install three screws (3).
b. Inspect (QA).
c. Perform AC power generation maintenance
operational check (TM 1-1520-238-T).
END OF TASK
2
1
3
M04-1315-3