TM 1-1520-238-23
9-119
9.33.
PILOT ELEC PWR PANEL REMOVAL/INSTALLATION continued
9.33.4. Cleaning
a. Clean removed and attaching parts or sur-
faces (para 1.47).
9.33.5. Inspection
a. Check removed and attaching parts for dam-
age (para 9.1).
b. Check mounting surface for stripped or dam-
aged threads (para 9.1).
c. Check connector for bent pins or damaged
threads (para 9.1).
d. Check removed and attaching parts for corro-
sion (para 1.49).
9.33.6. Installation
a. Enter pilot station (para 1.56). Observe all
safety precautions.
b. Attach connector (4) to panel (1).
(1) Attach connector P172 (4) to receptacle
(A125)J1 (5). Use socket head key set.
c. Install panel (1) on console (2).
(1) Position panel (1) on console (2).
(2) Lock four turnlock fasteners (3).
d. Perform electrical bonding check on panel
(TM 55-1500-323-24).
(1) Bond shall be 0.0025 OHM or less. Use
ohmmeter.
e. Inspect (QA).
f. Perform external power and ground service
utility receptacle maintenance operational
check (TM 1-1520-238-T).
END OF TASK
1
5
4
2
M04-1149-3
3
2
1
M04-1149-4