TM 1-1520-238-23
9-362
9.100.
ANTI-COLLISION LIGHT POWER SUPPLY REMOVAL/INSTALLATION continued
WARNING
The anti-collision light power supply
is high voltage. Wait 10 minutes after
power has been removed before main-
tenance, so that high voltage can dis-
charge. Failure to observe this
warning may result in death or injury
to personnel. If injury occurs, seek
medical aid.
c. Detach three connectors P102 (1), P103 (2),
and P104 (3) from power supply (4).
(1) Detach connector P102 (1) from receptacle
(PS5)J1 (5).
(2) Detach connector P103 (2) from receptacle
(PS5)J2 (6).
(3) Detach connector P104 (3) from receptacle
(PS5)J3 (7).
d. Remove cables (8) and (9) from bracket (10).
(1) Hold screw (11). Remove nut (12) and wash-
er (13).
(2) Remove screw (11), washer (14), and clamps
(15) and (16) from bracket (10).
(3) Push cables (8) and (9) inboard to access
power supply (4).
e. Remove power supply (4).
(1) Remove four screws (17) and washers (18).
(2) Remove power supply (4).
GO TO NEXT PAGE
4
1
M04-1243-2
18
11
5
3
6
2
7
M04-1243-4
13
16
16
15
8
9
9
17
14
15
12
10
8