TM 1-1520-238-23
9-418
9.114.
CPG CAUTION/WARNING PANEL REMOVAL/INSTALLATION
9.114.1. Description
This task covers:
Removal. Cleaning. Inspection. Installation.
9.114.2. Initial Setup
Tools:
Electrical tool kit (item 378, App H)
Ohmmeter (item 218, App H)
Personnel Required:
68X
Armament/Electrical System Repairer
68X3F
Armament/Electrical System Repairer/
Technical Inspector
References:
TM 1-1520-238-T
TM 55-1500-323-24
Equipment Conditions:
Ref
Condition
1.57
Helicopter safed
9.114.3. Removal
a. Enter CPG station (para 1.56). Observe all
safety precautions.
b. On CPG circuit breaker panel No. 1, open EM-
ERG BATT CAUT circuit breaker.
c. Remove CPG caution/warning panel (1) from
instrument panel (2).
(1) Open four turn fasteners (3).
d. Detach two connectors from panel (1).
(1) Detach connector P19 (4) from receptacle
(A157)J1 (5).
(2) Detach connector P31 (6) from receptacle
(A157)J2 (7).
GO TO NEXT PAGE
CPG STATION
M04-1295-1
1
5
3
4
M04-1295-2
6
2
7