TM 1-1520-238-23
9-416
9.113.
PILOT CAUTION/WARNING PANEL COIL L1 OR L2 REPLACEMENT (AVIM) continued
9.113.6. Installation
WARNING
Soldering iron can cause severe
burns to personnel and start fires.
Observe all safety precautions when
using soldering iron. If injury occurs,
seek medical aid.
NOTE
Perform step a if coil (A106)L1 was re-
moved.
Perform step b if coil (A106)L2 was re-
moved.
a. Install coil (10) on housing (2).
(1) Position new coil (10) on housing (2)
(TM 55-1500-323-24).
(2) Install screw (13) through housing (2) and coil
(10).
(3) Install nut (14) and washers (15) and (16) on
screw (13).
(4) Solder identified wires (11) to terminals (12).
Use soldering iron and solder (item 189,
App F) (TM 55-1500-323-24).
(5) Go to step c.
GO TO NEXT PAGE
15
16
12
11
10
M04-4220-5
14
VIEW
ROTATED
FOR CLARITY
13
2