TM 1-1520-238-23
9-436
9.117.
CPG CAUTION/WARNING PANEL COIL L1 OR L2 REPLACEMENT (AVIM) continued
b. Remove coil (A157)L1 (9) from housing (2).
(1) Identify and desolder wires (10) from coil ter-
minals
(11).
Use
soldering
iron
(TM 55-1500-323-24).
(2) Remove nut (12) and washers (13) and (14)
from screw (15).
(3) Remove screw (15) from coil (9) and housing
(2).
(4) Remove and discard coil (9).
9.117.4. Cleaning
a. Clean coil mounting area on CPG caution/
warning panel housing. Use isopropyl alcohol
(item 106, App F), brush (item 34, App F), and
cloth (item 52, App F).
9.117.5. Inspection
a. Check for cracks. None allowed.
b. Check removed and attaching parts for dam-
age (para 9.104).
c. Check wires and terminals for wear, cracks,
and cuts (para 9.104).
d. Check removed and attaching parts for corro-
sion (para 1.49).
e. Check connectors and receptacles for cracks,
broken connections, and bent or damaged
pins (para 9.104).
f. Check adjacent components for security of
attachment and loose mounting (para 9.104).
g. Check adjacent wiring and wire bundles for
cracked, broken, or burned insulation (para
9.104).
GO TO NEXT PAGE
10
15
M04-4222-3
14
13
12
9
11
2
ROTATED FOR
CLARITY