TM 1-1520-238-23
9-441
9.118.
CPG CAUTION/WARNING PANEL FIXED CAPACITOR C1 OR C2 REPLACEMENT
(AVIM) continued
WARNING
Discharge all capacitors by ground-
ing prior to removal. Capacitors can
hold an electrical charge and create a
dangerous potential for electrical
shock. If injury occurs, seek medical
aid.
Soldering iron can cause severe
burns to personnel and start fires.
Observe all safety precautions when
using soldering iron. If injury occurs,
seek medical aid.
CAUTION
Capacitors (A157)C1 and (A157)C2 are po-
larized electrolytic capacitors. Prior to re-
moval, identify capacitor leads to ensure
correct polarity during installation. Acciden-
tal polarity reversal will damage capacitor
and/or other internal components of CPG
caution/warning panel.
b. Remove capacitor (A157)C1 or (A157)C2 (4)
from component bracket clip (5).
(1) Identify capacitor leads (6).
(2) Desolder leads (6) from posts (7). Use
soldering iron (TM 55-1500-323-24).
(3) Remove and discard capacitor (4) and at-
tached sleeves (8).
GO TO NEXT PAGE
5
04-4223-3
4
7
6
8