TM 1-1520-238-23
9-438
9.117.
CPG CAUTION/WARNING PANEL COIL L1 OR L2 REPLACEMENT (AVIM) continued
b. Install coil (A157)L2 (1) on housing (2).
(1) Position new coil (1) on housing (2)
(TM 55-1500-323-24).
(2) Install screw (8) through housing (2) and coil
(1).
(3) Install nut (5) and washers (6) and (7) on
screw (8).
(4) Solder identified wires (3) to coil terminals (4).
Use soldering iron and solder (item 189,
App F) (TM 55-1500-323-24).
c. Inspect (QA).
d. Install CPG caution/warning connector
(A157)J2 (if removed) (para 9.116).
e. Install CPG caution/warning panel bottom ac-
cess cover (if removed) (para 9.116).
f. Install CPG caution/warning panel circuit
cards (A157)A1, (A157)A2, (A157)A3,
(A157)A4 and (A157)A5 (para 9.115).
g. Perform appropriate test. Electronic Equipment
Test Facility (E.E.T.F.) (TM 11-6625-3085-30).
END OF TASK
M04-4222-5
8
6
7
5
1
3
4
2