TM 1-1520-238-23
9-437
9.117.
CPG CAUTION/WARNING PANEL COIL L1 OR L2 REPLACEMENT (AVIM) continued
h. Check adjacent wiring and wire bundles for
missing or broken tie wraps, chafing, wear,
cuts, and breaks (para 9.104).
i. Check for deposits of dust or foreign matter
anywhere inside pilot caution/warning panel
housing. None allowed.
9.117.6. Installation
WARNING
Soldering iron can cause severe
burns to personnel and start fires.
Observe all safety precautions when
using soldering iron. If injury occurs,
seek medical aid.
NOTE
Perform step a if coil (A157)L1 was re-
moved.
Perform step b if coil (A157)L2 was re-
moved.
a. Install coil (A157)L1 (9) on housing (2).
(1) Position new coil (9) on housing (2)
(TM 55-1500-323-24).
(2) Install screw (15) through housing (2) and coil
(9).
(3) Install nut (12) and washers (13) and (14) on
screw (15).
(4) Solder identified wires (10) to coil terminals
(11). Use soldering iron and solder (item 189,
App F) (TM 55-1500-323-24).
(5) Go to step c.
GO TO NEXT PAGE
10
14
13
12
15
M04-4222-4
9
11
2
ROTATED FOR
CLARITY