TM 1-1520-238-23
9-452
9.120.
CPG CAUTION/WARNING PANEL CERAMIC FIXED CAPACITOR C5 REPLACEMENT
(AVIM) continued
9.120.5. Installation
a. Bond capacitor (1) to bracket (2).
NOTE
Capacitor markings must be visible.
Install capacitor with unmarked surface on
adhesive.
(1) Apply adhesive to capacitor (1). Use
adhesive (item 8, App F) and brush (item 34,
App F).
(2) Bond capacitor (1) to mounting surface of
bracket (2).
WARNING
Soldering iron can cause severe
burns to personnel and start fires.
Observe all safety precautions when
using soldering iron. If injury occurs,
seek medical aid.
b. Solder identified leads (3) to posts (4).
(1) Solder leads (3) to posts (4). Use soldering
iron
and
solder
(item 189, App F)
(TM 55-1500-323-24).
GO TO NEXT PAGE
4
3
1
2
M04-4225-3