TM 1-1520-238-23
9-590
Change 3
9.156.
KYK INTERFACE CONNECTOR ADAPTER REPLACEMENT
9.156.1. Description
This task covers:
Removal. Cleaning. Inspection. Installation.
9.156.2. Initial Setup
Tools:
Electrical tool kit (item 378, App H)
Personnel Required:
68X
Armament/Electrical System Repairer
68X3F
Armament/Electrical System Repairer/
Technical Inspector
References:
TM 11-1520-238-23-2
Equipment Conditions:
Ref
Condition
1.57
Helicopter safed
2.2
Access panel R194 removed
9.156.3. Removal
a. Remove W266 wire harness (1) from KYK in-
terface connector adapter (2).
(1) Detach J894 (3) from adapter (2).
GO TO NEXT PAGE
M04-5142-1
M04-5142-2
2
1
3