TM 1-1520-238-23
Change 3 9-595
9.158.
SQUAT SWITCH REPLACEMENT continued
9.158.3. Removal
a. Identify and depin two wires (1) from soft
splices (2) (TM 55-1500-323-24).
b. Identify and depin wire (3) from ground stud
(GS580) (4) (TM 55-1500-323-24).
c. Remove squat switch (5) from bracket (6).
(1) Remove two nuts (7) from bolts (8).
(2) Remove two bolts (8) and washers (9) from
switch (5) and bracket (6).
(3) Remove and discard switch (5).
9.158.4. Cleaning
a. Wipe removed and attaching parts with a
clean rag.
9.158.5. Inspection
a. Check mounting area for cracks. None al-
lowed.
b. Check mounting area for corrosion (para
1.49).
GO TO NEXT PAGE
M04-5166-2
1
3
4
2
5
6
7
8
9
M04-5166-3