TM 1-1520-238-23
Change 3
11-67
11.9.
LONGITUDINAL AND COLLECTIVE BELLCRANKS REMOVAL/INSTALLATION continued
11.9.6. Installation
WARNING
To prevent injury to personal or dam-
age to equipment, two persons are re-
quired for lifting and positioning
bellcranks. If injury occurs, seek med-
ical aid.
a. Position bellcrank (2) and bellcrank (1) for
installation on mixer supports (3) and (9).
(1) Install bushing (19) and bearing (20) in bell-
crank (2).
(2) Install bushing (17) and bearing (18) in bell-
crank (1).
(3) Aline bellcrank (2) with supports (3) and (9).
(4) Aline bellcrank (1) with supports (3) and (9)
and bellcrank (2).
GO TO NEXT PAGE
1
18
2
9
M04-1727-5A
20
17
19
3