TM 1-1520-238-23
11-234
11.49.
CYCLIC STICK ASE RELEASE SWITCH REPLACEMENT
11.49.1. Description
This task covers:
Removal. Cleaning. Inspection. Installation.
11.49.2. Initial Setup
Tools:
Electrical tool kit (item 378, App H)
Light duty laboratory apron (item 27, App H)
Heat protective gloves (item 155, App H)
Adjustable air filtering respirator (item 262, App H)
5-watt electric soldering iron (item 333, App H)
Materials/Parts:
Adhesive (item 14, App F)
Sealing compound (item 169, App F)
Solder (item 189, App F)
Personnel Required:
68X
Armament/Electrical System Repairer
68X3F
Armament/Electrical System Repairer/
Technical Inspector
References:
TM 1-1520-238-T
TM 55-1500-323-24
Equipment Conditions:
Ref
Condition
1.57
Helicopter safed
NOTE
This task is typical for either pilot or CPG
cyclic stick.
11.49.3. Removal
a. Enter pilot or CPG station (para 1.56). Observe
all safety precautions.
NOTE
Separate control grip from cyclic stick
only enough to allow wiring to be free of
obstruction.
b. Remove grip (1) from stick (2).
(1) Remove screw (3) and lockwasher (4).
GO TO NEXT PAGE
M04-3553-1
3
4
1
2