TM 1-1520-238-23
11-235
11.49.
CYCLIC STICK ASE RELEASE SWITCH REPLACEMENT continued
c. Debond and remove switch (5) from grip (1).
WARNING
Soldering iron can cause severe
burns to personnel and start fires.
Observe all safety precautions when
using soldering iron. If injury occurs,
seek medical aid.
d. Desolder wires (6) from switch (5) terminals.
(1) Identify and desolder wires (6). Use soldering
iron (TM 55-1500-323-24).
11.49.4. Cleaning
a. Clean adhesive from removed and attaching
parts (para 1.47).
11.49.5. Inspection
a. Check wires for cracked or broken insulation.
None allowed.
b. Check removed and attaching parts for
cracks. None allowed.
c. Check removed and attaching parts for dam-
age (para 11.5).
d. Check removed and attaching parts for corro-
sion (para 1.49).
GO TO NEXT PAGE
5
6
1
2
ROTATED FOR CLARITY
M04-3553-2