TM 1-1520-238-23
11-238
11.50.
CYCLIC STICK RADIO-ICS SWITCH REPLACEMENT
\
11.50.1. Description
This task covers:
Removal. Cleaning. Inspection. Installation.
11.50.2. Initial Setup
Tools:
Electrical tool kit (item 378, App H)
Light duty laboratory apron (item 27, App H)
Heat protective gloves (item 155, App H)
Adjustable air filtering respirator (item 262, App H)
5-watt electric soldering iron (item 333, App H)
Materials/Parts:
Adhesive (item 14, App F)
Solder (item 189, App F)
Tape (item 202, App F)
Personnel Required:
68X
Armament/Electrical System Repairer
68X3F
Armament/Electrical System Repairer/
Technical Inspector
References:
TM 11-1520-238-23-2
TM 55-1500-323-24
Equipment Conditions:
Ref
Condition
1.57
Helicopter safed
NOTE
This task is typical for either pilot or CPG
cyclic stick.
11.50.3. Removal
a. Enter pilot or CPG station (para 1.56). Observe
all safety precautions.
b. Remove grip cap (1).
(1) Remove adhesive from heads of five screws
(2) and screw (3).
(2) Remove five screws (2) and screw (3).
(3) Remove cap (1).
c. Debond and remove switch (4) from grip (5).
(1) Remove two nuts (6), washers (7), and
screws (8).
(2) Remove switch (4).
GO TO NEXT PAGE
M04-3554-1
3
2
1
4
7
6
5
8
