TM 1-1520-238-23
11-867
11.197.
CPG DIRECTIONAL CONTROL POSITION LINEAR VARIABLE DIFFERENTIAL TRANSDUCER
(LVDT) INSTALLATION continued
g. Install electrical lead (5) on ground stud (23).
(1) Position lead (5) on stud (23).
(2) Install washer (24) and nut (25).
(3) Apply sealing compound to nut (25). Use
sealing compound (item 175, App F).
h. Adjust LVDT null (para 11.216).
i. Remove CPG directional SPAD -9 rig pin (para
11.293).
j. Inspect (QA).
k. Perform directional flight control rigging
maintenance
operational
check
(TM 1-1520-238-T).
l. Install access door B65R; install covers B80R
and B85R; install fairing R60 (para 2.2).
m. Inspect (QA).
END OF TASK
M04-1852-7
5
23
24
25