TM 1-1520-238-23
11-871
11.199. CPG LATERAL CONTROL POSITION LINEAR VARIABLE DIFFERENTIAL TRANSDUCER (LVDT)
INSTALLATION
11.199.1. Description
This task covers:
Installation.
11.199.2. Initial Setup
Tools:
Aircraft mechanics tool kit (item 376, App H)
Electrical tool kit (item 378, App H)
0 - 30 inch-pound 1/4-inch drive dial indicator torque
wrench (item 445, App H)
Materials/Parts:
Cotter pin
Wire (item 222, App F)
Personnel Required:
67R
Attack Helicopter Repairer
68X
Armament/Electrical System Repairer
67R3F
Attack Helicopter Repairer/Technical
Inspector
References:
TM 1-1520-238-T
TM 55-1500-323-24
Equipment Conditions:
Ref
Condition
1.57
Helicopter safed
11.199.3. Installation
WARNING
Installation of an LVDT that has not
been EMI hardened in a BUCS
equipped aircraft may result in un-
commanded flight control movement.
This may cause loss of aircraft.
CAUTION
To prevent FOD from attaching and stick-
ing to the shaft, do not remove position
shaft from LVDT body during installation.
GO TO NEXT PAGE
M04-1854-1
M04-1854-2