TM 1-1520-238-23
Change 2
11-899
11.207.
PILOT COLLECTIVE CONTROL POSITION LINEAR VARIABLE DIFFERENTIAL TRANSDUCER
(LVDT) REMOVAL
11.207.1. Description
This task covers:
Removal. Cleaning. Inspection.
11.207.2. Initial Setup
Tools:
Aircraft mechanics tool kit (item 376, App H)
Electrical tool kit (item 378, App H)
Personnel Required:
67R
Attack Helicopter Repairer
68X
Armament/Electrical System Repairer
References:
TM 55-1500-323-24
Equipment Conditions:
Ref
Condition
1.57
Helicopter safed
11.44
Pilot collective stick cover removed
11.207.3. Removal
a. Enter pilot station (para 1.56). Observe all
safety precautions.
b. On pilot center circuit breaker panel, open
ASE AC, DC, and BUCS circuit breakers.
GO TO NEXT PAGE
M04-1745-1A
PILOT STATION LEFT SIDE