TM 1-1520-238-23
11-937
11.216.
LINEAR VARIABLE DIFFERENTIAL TRANSDUCER (LVDT) ADJUSTMENT continued
NOTE
If filter adapters are installed, go to step
s.(1). If filter adapters are not installed, go
to step s.(2).
s. Attach connectors P688 (11) and P686 (12) to
receptacles (14) and (15) on DASE computer
(13).
(1) Attach connector P686 (12) to filter adapter
A707 (17) and connector P688 (11) to filter
adapter A708 (16) on DASE computer (13).
(2) Attach connector P686 (12) to connector J2
(15) and connector P688 (11) to connector J1
(14) on DASE computer (13).
t. Inspect (QA).
u. External primary hydraulic power discon-
nected (para 1.72).
v. Remove
rig
pins
as
required
(TM 1-1520-238-T).
w. Inspect (QA).
x. Perform DASE maintenance operational
check (TM 1-1520-238-T).
END OF TASK
13
15
12
14
11
M04-3085-13
17
12
16
11
13
M04-3085-6