TM 1-1520-238-23
11-932
11.216.
LINEAR VARIABLE DIFFERENTIAL TRANSDUCER (LVDT) ADJUSTMENT continued
WARNING
Turn off power before disconnecting
or reconnecting wires and connec-
tors. High current VDC 28 and/or 115
VAC is present. Failure to do so could
result in death or serious injury. If inju-
ry occurs, seek medical aid.
f. Check for 26 VAC at the corresponding LVDT.
(1) To check for 26 VAC at pilot collective LVDT
(1) or CPG collective LVDT (2):
(a) Detach connector P230 (3) from recep-
tacle J230 (4) or connector P234 (3) from
receptacle J234 (4).
(b) Check for 26 VAC at the corresponding
LVDT connector pins (para 11.217, Table
5). Use multimeter (TM 55-1500-323-24).
(2) To check for 26 VAC at pilot longitudinal LVDT
(5) or CPG longitudinal LVDT (6):
(a) Detach connector P232 (3) from recep-
tacle J232 (4) or connector P236 (3) from
receptacle J236 (4).
(b) Check for 26 VAC at the corresponding
LVDT connector pins (para 11.217, Table
5). Use multimeter (TM 55-1500-323-24).
GO TO NEXT PAGE
PILOT STATION
M04-3085-7
5
6
2
1
CPG STATION
M04-3085-1
3
4