TM 1-1520-238-23
11-934
11.216.
LINEAR VARIABLE DIFFERENTIAL TRANSDUCER (LVDT) ADJUSTMENT continued
NOTE
If filter adapters are installed, go to step
g.(1). If filter adapters are not installed, go
to step g.(2).
g. Detach connectors P688 (11) and P686 (12)
from DASE computer (13).
(1) Detach connector P688 (11) from filter adapt-
er A708 (14) and connector P686 (12) from
filter adapter A707 (15) on DASE computer
(13).
(2) Detach connector P688 (11) from connector
J1 (16) and connector P686 (12) from con-
nector J2 (17) on DASE computer (13).
GO TO NEXT PAGE
M04-3085-5
M04-3085-3
13
15
12
14
M04-3085-12
11
17
12
16
11
13
M04-3085-4