TM 1-1520-238-23
11-1027
11.242.
CPG DIRECTIONAL CONTROL PEDAL RELEASE SHAFT ASSEMBLY
REMOVAL/INSTALLATION continued
11.242.3. Removal
a. Enter CPG station (para 1.56). Observe all
safety precautions.
b. Remove pedal adjust cover (1) and shield (2)
from armor panels (3).
(1) Remove six nuts (4) and washers (5) from
panels (3).
(2) Remove cover (1) and shield (2).
c. Remove pedal release handle (6) from pedal
support (7).
(1) Remove and discard cotter pin (8).
(2) Remove nut (9).
(3) Remove bolt (11) and washer (10) from han-
dle (6) and pedal support (7).
(4) Remove handle (6).
d. Remove shaft (12) from pedal adjust crank
(13).
(1) Remove and discard cotter pin (14).
(2) Remove nut (15).
(3) Remove bolt (16) and bushing (17) from shaft
(12).
(4) Remove shaft (12) and crank (13).
GO TO NEXT PAGE
5
4
2
1
M04-4436-2
3
11
13
14
6
12
8
M04-4436-3
15
16
7
17
10
9