TM 1-1520-238-23
12-106
12.34.
PILOT ENGINE FIRE PULL SWITCH REMOVAL/INSTALLATION - continued
e. Enter CPG station (para 1.56). Observe all
safety precautions.
WARNING
Soldering gun can cause severe burns
to personnel and start fires. Observe
all safety precautions when using
soldering gun. If injury occurs, seek
medical aid.
f. Desolder wires (6) from switch (2).
(1) Remove sleeving (7) from wires (6).
(2) Identify and desolder wires (6) from terminals
(8). Use soldering gun (TM 55-1500-323-24).
g. Identify and detach two wires (9) from wires
(10).
(1) Remove and discard two splices (11)
(TM 55-1500-323-24).
12.34.4. Cleaning
a. Wipe removed and attaching parts with a
clean rag.
12.34.5. Inspection
a. Check switches for cracks and broken or
loose terminals (para 12.33).
b. Check wires for cuts, nicks, fraying, or chaf-
ing (para 12.33).
c. Check removed and attaching parts for corro-
sion (para 1.49).
GO TO NEXT PAGE
6
2
6
9
11
10
8
7
M04-984-4