TM 1-1520-238-23
12-121
12.38.
PRIMARY AND RESERVE FIRE EXTINGUISHER REMOVAL - continued
NOTE
This task is typical for primary or reserve
fire extinguishers.
12.38.3. Removal
a. Enter pilot station (para 1.56). Observe all
safety precautions.
b. On pilot center circuit breaker panel, open
FIRE EXTGH PLT, CPG, and APU circuit break-
ers.
c. Install shorting wire (1) on cartridge (2).
(1) Cut 4 INCH length of lockwire. Use wire
(item 226, App F).
(2) Wrap one end of wire around terminal (3).
Wrap other end of wire around terminal (4).
d. Install shorting wire (5) on cartridge (6).
(1) Cut 4 INCH length of lockwire. Use wire
(item 226, App F).
(2) Wrap one end of wire around terminal (7).
Wrap other end of wire around terminal (8).
e. Install shorting wire (9) on cartridge (10).
(1) Cut 4 INCH length of lockwire. Use wire
(item 226, App F).
(2) Wrap one end of wire around terminal (11).
Wrap other end of wire around terminal (12).
GO TO NEXT PAGE
M04-995-2
2
3
1
4
M04-995-3
6
7
5
8
9
12
11
10