15.43.
APU ENCLOSURE SUPPORT BRACKETS REMOVAL/INSTALLATION - continued
b. Install bracket (1) on support (2).
(1) Lightly wipe mating surfaces of bracket (1)
and support assembly (2). Use methyl ethyl
ketone (item 124, App F) and clean rag.
(2) Position enclosure panel (8). Install three fas-
teners (9) in bracket (1).
(3) Mark position of bracket (1) on support (2).
Do not mark on mating surfaces.
(4) Remove fasteners (9) from bracket (1). Re-
move panel (8).
(5) Spread a thin, uniform layer of adhesive on
mating surfaces. Use adhesive (item 3,
App F) and depressor (item 70, App F).
(6) Aline bracket (1) with marks on support (2).
Press together. Clamp in place. Use C clamp.
(7) Cure adhesive 1 HOUR minimum at 190 to
210 F (87 to 98 C). Use heater.
(8) Remove C clamp.