TM 1-1520-238-23
16-62
Change 8
16.13.
PYLON ACTUATOR ROD END REMOVAL/INSTALLATION
16.13.1. Description
This task covers:
Removal. Cleaning. Inspection. Installation.
16.13.2. Initial Setup
Tools:
Electrical tool kit (item 378, App H)
0 - 600 inch-pound 3/8-inch drive dial indicator torque
wrench (item 447, App H)
Materials/Parts:
Cotter pin
Wire (item 225, App F)
Personnel Required:
68X
Armament/Electrical System Repairer
68X3F
Armament/Electrical System Repairer/
Technical Inspector
References:
TM 9-1230-476-20-1
Equipment Conditions:
Ref
Condition
1.57
Helicopter safed
16.3
Pylon rack ejector impulse cartridge re-
moved
16.13.3. Removal
a. Remove actuator rod end (1) from yoke (2).
(1) Remove and discard cotter pin (3).
(2) Hold bolt (4). Remove nut (5) and washer (6).
(3) Remove bolt (4) from yoke (2) and rod end
(1).
(4) Remove rod end (1) from yoke (2).
GO TO NEXT PAGE
M04-3397-1
M04-3397-2
2
4
1
6
3
5